Certificate/Reg.-No. | 968/FSA 1045.00/15 |
Type of Certificate | FSA Certificate |
Certificate Holder | Frames Energy Systems B.V. |
Manufacturer | Frames Energy Systems B.V. |
Product Category | Safety Instrumented Systems / SRECS / Safety Functions > HIPPS |
Subject | HIPPS valves (subsystem Final Elements with actuator and local panel) including corresponding design and engineering documentation |
Type Designation | FRAMES Ref.: EVO100583 |
Codes and Standards |
|
Scope and Result | The assessment covers phases 4 and 5 (limited to validation) of the safety lifecycle of IEC 61511. Subsystems Logic Solver and Sensor are out of scope of the assessment. Safety Function: HIPPS valves prevent over pressurization of the FSPO Saxi Batuque in Angola. The valves are designed to close in case of a demand. Result: The HIPPS valves comply with the applicable requirements of IEC 61511 for SIL 3. |
Specific Provisions | The instructions given by the supplier of the subsystem Final Elements (safety manual) and the safety documentation delivered by the component suppliers have to be observed. Mode of operation: Low Demand Mode; Proof test interval: 1 year; Response time: 4 sec (limited to the subsystem Final Elements); MTTR: less 72 h Calculated average probability of failure on demand PFD_FE=4.76E-4. Any change in type of used hardware design requires a reconsideration and impact analysis of the modified system. |
Valid Until | no expiry date |
Appendixes | n/a |
Download Certificate | 968_FSA_1045_00_15_en_el.pdf |
Certificate/Reg.-No. | Certificate Holder | Product Category | Product Tested | Type Designation | Details |
---|
968/FSA 1045.00/15 | Frames Energy Systems B.V. | Safety Instrumented Systems / SRECS / Safety Functions → HIPPS | HIPPS valves (subsystem Final Elements with actuator and local panel) including corresponding design and engineering documentation | FRAMES Ref.: EVO100583 | View Details | View PDF |
Remark: In case of missing entries this is due to restrictions by the certificate holder