Certificate/Reg.-No. | 01/205/5318.01/18 |
Type of Certificate | EC Type-Examination Certificate (Machinery Directive) |
Certificate Holder | IDEM Safety Switches Ltd. |
Product Category | Sensors, Transmitters, Guards > Position / Proximity Switches Logic Units > Monitoring Devices |
Product Tested | Coded non-contact stand-alone safety interlock switches |
Type Designation | PSA, MSA |
Codes and Standards |
|
Intended Application | The coded non-contact stand alone safety interlock switches form a PDDB in accordance with EN 60947-5-3 and comply with the requirements of Category 4 / PL e and SIL 3 in accordance with EN ISO 13849-1 and EN 62061 / EN 61508. |
Specific Requirements | The instructions of the associated Installation and Operating Manual shall be considered. In PL e applications in which operational processes do not ensure that the safety function is demanded regularly (≥ 1/month), organizational measures must be taken to ensure that it is tested manually at least once a month. |
Valid Until | 2023-05-24 (Certificate expired) |
Appendixes | n/a |
Download Certificate | 01_205_5318_01_18_en_el.pdf |
Certificate/Reg.-No. | Certificate Holder | Product Category | Product Tested | Type Designation | Details |
---|
01/205/5318.01/18expired | IDEM Safety Switches Ltd. | Sensors, Transmitters, Guards → Position / Proximity Switches | Coded non-contact stand-alone safety interlock switches | PSA, MSA | View Details | View PDF |
01/205/5318.01/18expired | IDEM Safety Switches Ltd. | Logic Units → Monitoring Devices | Coded non-contact stand-alone safety interlock switches | PSA, MSA | View Details | View PDF |
Remark: In case of missing entries this is due to restrictions by the certificate holder