Certificate/Reg.-No. | 968/INS 209.00/19 |
Type of Certificate | INS Certificate |
Certificate Owner | Eltex-Elektrostatik GmbH |
Product Category | Logic Units > Safety PLCs > Controllers |
Product | Safety Functions within the Power Charger and System Master Variants |
Type Designation | PC [a] / [b] [c] [d] [e] [f] [g] [h] [i] [j] a = SC, TL, DC, RM, RT, MT; b = X, C, P; c=N, P; d = 3; e = L, S, H; f = A - Z or 0 - 9; g = X, D; h = A – Z or 0 – 9; i = P, D; j = 000 – 999 |
Standards applied for inspection |
|
Inspection Results | The safety functions comply with the requirement for PL d in accordance with EN ISO 13849-1: SF1: The charging voltage shall only be generated if requested by the enable signal, if the discharge earth monitoring does not report a fault and if no overvoltage has been measured at the charging electrodes. SF2: The discharge voltage shall only be generated if requested by the enable signal, if the corresponding ground monitoring does not report a fault and if no overvoltage has been measured at the discharge bars. |
Validity | [undisclosed] |
Inspection Periond | 2019-03-01 - 2019-09-12 |
Appendixes | n/a |
Download Certificate |
968_INS_209_00_19_en_el.pdf 968_INS_209_00_19_de_el.pdf |
Certificate/Reg.-No. | Certificate Holder | Product Category | Product Tested | Type Designation | Details |
---|
968/INS 209.00/19 | Eltex-Elektrostatik GmbH | Logic Units → Safety PLCs → Controllers | Safety Functions within the Power Charger and System Master Variants | PC [a] / [b] [c] [d] [e] [f] [g] [h] [i] [j] a = SC, TL, DC, RM, RT, MT; b = X, C, P; c=N, P; d = 3; e = L, S, H; f = A - Z or 0 - 9; g = X, D; h = A – Z or 0 – 9; i = P, D; j = 000 – 999 | View Details | View PDF |
Remark: In case of missing entries this is due to restrictions by the certificate holder