Certificate/Reg.-No. | 01/205/5747.00/19 |
Type of Certificate | EC Type-Examination Certificate (Machinery Directive) |
Certificate Holder | Eaton Industries GmbH |
Product Category | Logic Units > Power Drive Systems (safety-related) |
Product Tested | Integrated Safety Function STO within the Variable Frequency Drive Inverters |
Type Designation | x1 = 2, 4, 5, 8; x2 = 2, 4; x3 = 0, 2; x4 = 0, 1, 2, 4; x5 = A, E, P; x6 = 3, I, N; x7 = 1, 2, P, T; x8 = 5, 4; x9 = 0, R; x10 = 0, 1; x11 = 0, 1 |
Codes and Standards |
|
Intended Application | Safe Torque Off (STO) within the Variable Frequency Drive Inverters. The safety function complies with the requirements of PL e / Cat. 3 according to EN ISO 13849-1 and SIL 3 / SIL CL 3 of IEC 61800-5-2 / IEC 61508 / IEC 62061 and can be used in applications up to these safety levels. |
Specific Requirements | The instructions as mentioned in the associated installation and operating manual shall be considered. A periodic demand of the safety function of at least once every three month is required in order to ensure sufficient diagnostic. |
Valid Until | 2024-08-05 |
Appendixes | n/a |
Download Certificate | 01_205_5747_00_19_de_en_el.pdf |
Certificate/Reg.-No. | Certificate Holder | Product Category | Product Tested | Type Designation | Details |
---|
01/205/5747.00/19 | Eaton Industries GmbH | Logic Units → Power Drive Systems (safety-related) | Integrated Safety Function STO within the Variable Frequency Drive Inverters | x1 = 2, 4, 5, 8; x2 = 2, 4; x3 = 0, 2; x4 = 0, 1, 2, 4; x5 = A, E, P; x6 = 3, I, N; x7 = 1, 2, P, T; x8 = 5, 4; x9 = 0, R; x10 = 0, 1; x11 = 0, 1 | View Details | View PDF |
Remark: In case of missing entries this is due to restrictions by the certificate holder