Certificate/Reg.-No. | 01/205/5578.03/22 |
Type of Certificate | EC Type-Examination Certificate (Machinery Directive) |
Certificate Holder | Delta Electronics, Inc. |
Product Category | Logic Units > Power Drive Systems (safety-related) |
Product Tested | Safety Function “Safe Torque Off” within the AC motor drive |
Type Designation | MH300 series: VFDXXXMHXXXXSXA MS300 series: VFDXXXMSXXXXSXA ME300 series: VFDXXXMEXXXXSXA TDU series: TDUxxxEx00 Details see Revision List |
Codes and Standards |
|
Intended Application | The safety function “Safety Torque Off” complies with the requirements of the relevant standards (SIL 2 according to EN/IEC 61800-5-2 / EN/IEC 61508, maximum SIL 2 according to EN IEC 62061, PL d / Cat. 3 according to EN ISO/ISO 13849-1) and can be used in applications up to these safety levels. The products can be used in the application area of EN 60204-1:2018 and IEC 60204-1:2016 + AMD1:2021. |
Specific Requirements | The instructions of the associated safety manuals and user manuals shall be considered. In order to maintain the pollution degree 2 the devices shall be mounted in a cabinet of IP54 or better, or other pollution controlled environment. |
Valid Until | 2027-08-08 |
Appendixes | 01_205_5578_03_22_RL_2022_08_08.pdf |
Download Certificate | 01_205_5578_03_22_en_el.pdf |
Certificate/Reg.-No. | Certificate Holder | Product Category | Product Tested | Type Designation | Details |
---|
01/205/5578.03/22 | Delta Electronics, Inc. | Logic Units → Power Drive Systems (safety-related) | Safety Function “Safe Torque Off” within the AC motor drive | MH300 series: VFDXXXMHXXXXSXA MS300 series: VFDXXXMSXXXXSXA ME300 series: VFDXXXMEXXXXSXA TDU series: TDUxxxEx00 Details see Revision List | View Details | View PDF |
Remark: In case of missing entries this is due to restrictions by the certificate holder