Certificate/Reg.-No. | 01/205/5450.02/23 |
Type of Certificate | EC Type-Examination Certificate (Machinery Directive) |
Certificate Holder | Autec S.r.l. |
Product Category | Logic Units > Relay Safety Modules |
Product Tested | Emergency stop function within the wireless control |
Type Designation | AIR series wireless control: Transmitters: model A08 / type LA0AM, A08S / type LA0AM Receivers: model RGA / type GA00M, model RGE / type BA00M |
Codes and Standards |
|
Intended Application | Emergency Stop Function (Stop Cat. 0) The emergency stop function within the AIR series wireless control complies with the requirements of the relevant standards in combination with transmitter model: - A08: Cat. 3 / PL d acc. to EN ISO / ISO 13849-1, SIL 2 acc. to EN / IEC 61508 - A08S: Cat. 4 / PL e acc. to EN ISO / ISO 13849-1, SIL 3 acc. to EN / IEC 61508 and can be used in applications up to these safety levels. Furthermore, the devices can be used in the application area of EN IEC / IEC 62061:2021, EN ISO / ISO 13850:2015 and EN 60204-1:2018 / IEC 60204-1:2016. |
Specific Requirements | The instructions of the associated User Manual and the Technical Datasheet shall be considered. |
Valid Until | 2028-09-13 |
Appendixes | n/a |
Download Certificate | 01_205_5450_02_23_en_el.pdf |
Certificate/Reg.-No. | Certificate Holder | Product Category | Product Tested | Type Designation | Details |
---|
01/205/5450.02/23 | Autec S.r.l. | Logic Units → Relay Safety Modules | Emergency stop function within the wireless control | AIR series wireless control: Transmitters: model A08 / type LA0AM, A08S / type LA0AM Receivers: model RGA / type GA00M, model RGE / type BA00M | View Details | View PDF |
Remark: In case of missing entries this is due to restrictions by the certificate holder